2019Laboratory StudyMechanistic finding

Which proteins did two commercial serum zonulin assays capture?

Study sample
Serum comparisons included 36 people with non-celiac wheat sensitivity, 37 with celiac disease, 20 with ulcerative colitis and 49 healthy controls. A separate comparison ran 28 samples on both kits.
What was tested
Researchers compared serum readings in several gastrointestinal conditions, ran the same samples through two kits, and identified captured proteins by mass spectrometry. They tested whether the kits recognized a purified standard of the protein called zonulin, prehaptoglobin-2.
Result
One kit gave higher readings in all three patient groups than in healthy controls. When the same samples went through the two kits, their readings agreed poorly. Both kits captured the blood protein complement C3. One also captured haptoglobin.