2022Observational StudyNegative or null finding

A commercial receptor antibody panel gave similar results in POTS and healthy controls

Study sample
116 people with POTS and 81 healthy controls at two centers
What was tested
A commercial ELISA measured blood antibody concentrations against 11 receptors involved in cardiovascular regulation. Researchers compared concentrations, manufacturer-defined positive results and the ability of each measurement to distinguish the groups.
Result
Antibody levels were similar in both groups. At the manufacturer’s threshold for the α1 adrenergic receptor, 98% of people with POTS and all healthy controls tested positive.