Skip to content
← Back to study summaries
2019Double-Blind RCTMixed findings

Wrist monitors recorded more efficient sleep after four weeks of an αs1-casein preparation

Study sample
48 Korean adults with mild to moderate sleep disturbance randomized, 43 completed both periods
What was tested
In a crossover trial, participants took a capsule containing partially digested αs1-casein and a matched placebo for four weeks each, separated by a four-week washout. They kept sleep diaries and wore wrist monitors. A subgroup also slept in the laboratory.
Result
The wrist monitor estimated that time spent asleep rose from 84% to 88% of time in bed during the casein period and from 83% to 84% during placebo. Sleep diaries also favored casein. Overnight laboratory recordings and the standard sleep questionnaires showed no clear difference between periods.