2022Observational StudyNegative or null finding
A commercial receptor antibody panel gave similar results in POTS and healthy controls
Hall J, Bourne KM, Vernino S et al. · Circulation
- Study sample
- 116 people with POTS and 81 healthy controls at two centers
- What was tested
- A commercial ELISA measured blood antibody concentrations against 11 receptors involved in cardiovascular regulation. Researchers compared concentrations, manufacturer-defined positive results and the ability of each measurement to distinguish the groups.
- Result
- Antibody levels were similar in both groups. At the manufacturer’s threshold for the α1 adrenergic receptor, 98% of people with POTS and all healthy controls tested positive.