Which proteins did two commercial serum zonulin assays capture?

Ajamian M, Steer D, Rosella G, Gibson PR

Serum comparisons included 36 people with non-celiac wheat sensitivity, 37 with celiac disease, 20 with ulcerative colitis and 49 healthy controls. A separate comparison ran 28 samples on both kits.

One kit gave higher readings in all three patient groups than in healthy controls. When the same samples went through the two kits, their readings agreed poorly. Both kits captured the blood protein complement C3. One also captured haptoglobin.