Skip to content
Body–Brain Atlas
Reading mode
ConditionsAutonomic

Postural Orthostatic Tachycardia Syndrome (POTS)

2006Clinical TrialMixed findings

Standing pulse and standing time after a somatostatin analogue

Hoeldtke RD, Bryner KD, Hoeldtke ME, Hobbs G

9 people with POTS and a separate group of 6 with orthostatic intolerance

In the nine people with POTS, standing pulse averaged 114 beats per minute at baseline and about 91 with octreotide. Midodrine also lowered pulse. Only on the day participants received both drugs did their average standing time increase, from about 41 to 56 minutes.